Features
- Combines passive infrared (PIR) and ultrasonic technologies
- Auto set automatically selects optimal settings for each space
- Walk-through mode increases savings potential
- Built-in light level sensor
- Accepts low-voltage switch input for manual-on operation
- Automatic or manual-on operation when used with a BZ-150 Power Pack
- Ceiling and Wall Mount
Specifications
General Info
| Color | White | ||
| Product Series | DT-200 | ||
| Type | Sensor | ||
| Material | ABS | ||
| Finish | Glossy | ||
| Application Sector | Commercial | ||
| Product Line | Wattstopper | ||
| Country Of Origin | China | ||
| Features | Adjustable Time Delay, Indicator Lights, Isolated Relay, Light Level Sensor, Power Pack Required, Sensitivity Adjustment, Test Mode, Walkthrough Mode | ||
| Included | J-Box Cover Plate, Sensor Mask, Swivel Bracket | ||
| Installation Location | Ceiling, Wall | ||
| Switch Type | Motion Sensor | ||
| Warranty Type | 5-Year | ||
| Standard | UL, cUL | ||
| UPC Number | 754182914180 |
Dimensions
| Product Depth US | 3.1 in | ||
| Product Height US | 4.3 in | ||
| Product Volume US | 66.1 cu in | ||
| Product Width US | 3.4 in | ||
| Product Weight US | 0.3 lb |
Additional Information
| Security | Yes | This product is ioXt certified | |
| RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
| Current Draw | 33 mA | ||
| Number of Rockers | 0 | ||
| On Function | Auto On | ||
| Wire Connection Type | Flying Leads | ||
| Compatibility | BZ Power Packs, Wattstopper PLUS Sensor Interface Module | ||
| Has Battery | No | ||
| Indicator | PIR Detection LED, Ultrasonic Detection LED | ||
| Indoor/Outdoor | Indoor | ||
| Input Voltage | 18 to 28 VDC/VAC | ||
| Light Level Adjustment | 10-200 fc | ||
| Load Rating | 1 A @ 30 VDC | ||
| Location Rating | Dry | ||
| Mounting Type | J-Box, Surface, Swivel Bracket | ||
| Number of Buttons | 0 | ||
| Timer Type | DIP Switch | ||
| Timer Duration | 30 Seconds, 5-30 Minutes | ||
| Operating Temperature | 0°-55°C, 32°-131°F | ||
| Operating Temperature Max | 131 °F | ||
| Operating Temperature Min | 32 °F | ||
| Operating Humidity | 5-95% RH (Non-Condensing) | ||
| Sensing Range | 38 ft, 55 ft | ||
| Sensitivity Adjustment | PIR (Min/Max), Ultrasonic (Min/Max) | ||
| Sensor Type | Occupancy | ||
| Sensor Technology | Dual Technology, Passive Infrared (PIR), Ultrasonic | ||
| Sensor Coverage | 2000 sq ft | ||
| Sensor Coverage Pattern | 90 ° | ||
| Sensor Mounting Height | 10 ft | ||
| Ultrasonic Frequency | 40 kHz | ||
| Storage Temperature | 23° - 176° F, -5° - 80° C | ||
| Engraving Type | Blank |
Resources
Instruction Sheet
CAD Drawings
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
dxf
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
pdf
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
png
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
dwg
57-003-1 - Any 8-Wire Occupancy Sensor "Standard Schematic"
pdf
57-010 - Multiple Occupancy Sensors Using One Power Pack
dxf
57-010 - Multiple Occupancy Sensors Using One Power Pack
png
57-010 - Multiple Occupancy Sensors Using One Power Pack
dwg
57-010 - Multiple Occupancy Sensors Using One Power Pack
pdf
57-039-5 - DT-200/CX Series Mounting Detail with Pendant Mounted Fixtures
dxf
57-039-5 - DT-200/CX Series Mounting Detail with Pendant Mounted Fixtures
dwg
57-039-5 - DT-200/CX Series Mounting Detail with Pendant Mounted Fixtures
pdf
57-039-6 - DT & CX Series Sensor Installation
png
57-039-6 - DT & CX Series Sensor Installation
pdf
57-039-6 - DT & CX Series Sensor Installation
dxf
57-039-6 - DT & CX Series Sensor Installation
dwg
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
dxf
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
dwg
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
pdf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dxf
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
dwg
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
pdf
DT-200
png
DT-200
dwg
DT-200
dxf
DT-200cp - DT-200 Coverage Pattern
dxf
DT-200cp - DT-200 Coverage Pattern
png
DT-200cp - DT-200 Coverage Pattern
dwg
57-039-5 - DT-200/CX Series Mounting Detail with Pendant Mounted Fixtures
png
57-041-1 - 8-Wire Sensor Interfacing With A Thermostat
png
60-601-2 - LI/LP Relay Panels Occupancy Sensor Connection
png
View More
Specifications
Case Studies
Watt Stopper/Legrand helps NRG Systems realize big savings
pdf
The Watt Stoppers Dual Technology Occupancy Sensors Save $11,500/year at Des Moines Area Community College
pdf
Lighting Controls from The Watt Stopper Contribute to "Greenest" Building
pdf
The Watt Stopper Occupancy Sensors Reduce University Lighting Load by 30%
pdf
View More
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Bazaarvoice SAP Hybris Integration Version 2.8.1